Oscillator PressureSets oscillatory amplitude or Delta P of waveform +-40 cmH2O,D 80 cmH2O
Pressure Range+-65 cmH2O,3 modes,maximum,mean,minimum
CPAP/PEEP RegulatorAirways pressure 0-35 cmH2O
Graphic DisplayControls sweep speed over the screen 0.5 to 6 sec
Pressure Display SwitchMaximum-Mean-Minimum digital display of airway pressures (in both ventilator modes)
Voltage Power100-120 V
Indicators FreezeHolds display on screen
HFO Inspiratory Expiratory Phase1:1
PowerGreen LED indicates power on
Manual BreathGives single breath in CPAP,CMV and PTV modes to preset inspiration time
HFO Operational Frequency3-20 Hz
Frequency50/60 Hz
ScreenSuperbright pressure display of all ventilation waveforms
Ventilator Max Inspiratory Time (Insp Time)0.1-3 sec
Ventilator I.E. Ratio9.9:1 to 1:99 calculated from BPM and MIT settings
HFO ModesOff,Expiratory,Inspiratory,Continuous
Oxygen Blender21-100% O2 +-3%
Inspiratory PressureAdjusts inspiratory pressure 0-60 cmH2O
Ventilator Breathing1-150 BPM
Size, Ventilator Only37 cm x 34 cm x 32 cm (W x H x D)
Air and O23-5 bar
Model NumberSLE 2000
Weight, Ventilator Only16 Kg
Screen Switch+-60 cmH2O for oscillation only mode -5 to +60 cmH2O for ventilation/scillation mode
PTV ThresholdAdjustable for patient effort required to trigger ventilator
Height on Pole141 cm
Pressure Bar DisplayPressure Gauge Range -10 to +70 cmH2O
FiO2 Oxygen Percentage21-100%
Conventional VentilatorOff/Alarm Test,CPAP,CMV,PTV,SIMV


SLE3600 Inosys Nitric Oxide Therapy:

  • The SLE Inosys Inhaled Nitric Oxide delivery system delivers low concentration NO therapy with typical concentrations being in the range of 2-80 ppm. The Inosys is usable with any constant-flow ventilator, and is an ideal add-on for the SLE2000, SLE2000 HFO, SLE4000 and SLE5000 ventilators. With user-settable alarms for high and low concentrations, the unit automatically reduces therapy if an alarm is triggered
  • Monitors both NO and NO2
  • Alarms for both NO and NO2
  • Long-life cells
  • Internal printer 
  • Simple calibration
  • Internal battery back-up 
  • Can be used on any constant-flow ventilator


Air Compressor:

  • A free-standing air compressor is also available for use with the SLE2000 HFO. Please see your local distributor for further details


Screen Displays:

  • The high-resolution LCD (Liquid Crystal Display) is used to show waveforms, including high frequency modes


SLE2000 HFO with Single-use Circuits:

  • Stand-mounted ventilator  complete with a servo-  controlled humidifier -    typically a Fisher & Paykel  (or equivalent), air and    Oxygen hoses and manual  (3 single-use patient circuits  included for user start-up).  Includes 2 pin European- style plug.


SLE2000 HFO with Reusable Circuit:

  • Stand-mounted ventilator  complete with a servo-  controlled humidifier -    typically a Fisher & Paykel (or equivalent), air and Oxygen  hoses and manual (reusable  patient circuit included for  user start-up). Includes 2 pin  European-style plug


Product Details:

  • Exceptional pneumatic performance
  • The operation of the unique valveless system eliminates the need for exhalation valves, diaphragms etc. meaning less to clean and easier, safer assembly
  • The simple patient circuit (suitable for all modes of ventilation), together with the valveless system, reduces problems of resistance and compliance
  • The principle of operation of the valveless system reduces inadvertent PEEP, and aids in the total clearance of expired gases
  • Automatic gas flow adjustment
  • Ability to maintain pressure waveforms at all rates
  • Sensitive airway pressure trigger
  • Comprehensive alarm system
  • Built in oxygen analyser with continuous digital readout
  • Clear and easily set controls, including tamper-proof pneumatic controls
  • High pressure relief, on alarm
  • Exhaled gases can be filtered
  • Optional auxiliary blended flow outlet
  • Choice of square or slow rise time, switch selectable
  • Ability to entrain other gases e.g. Nitric Oxide


Indicators:

  • System Fail: Indicates main processor system fail
  • BPM Display: Breaths per minute
  • Insp Time Display: Inspiratory time
  • IE Ratio: Inspiration to expiration ratio
  • Trigger Back up: Indicates a machine delivered breath ifpatient fails to trigger ventilator duringuser-controlled back-up time window
  • CPAP/PEEP: Indicator for set up of pressures
  • Oscillator Gauge: Indicator for set up of pressures
  • Inspiratory Gauge: Indicator for set up of pressures


Alarms:

  • HFO Fail: Motor drive to oscillator failure
  • Fan Fail: Motor fan failure
  • High/Cycle/Low: User adjusted, visual and 7 Hz, intermittent audible
  • Block-Leak: Of fresh gas - visual and  continuous audible
  • Mute: 60 seconds
  • Reset: Resets all alarms except system fail, HFO and fan fail
  • Loss of Mains: Battery powered, audible
  • Loss of Air or Oxygen: Pneumatic, audible from blender